ZEMCH 2015 - International Conference Proceedings | Page 859
International Conference | Bari - Lecce, Italy
Session XII
GREEN WALLS FOR A SUSTAINABLE CONTROL OF
BUILDING MICROCLIMATE
Evelia Schettini1, Ileana Blanco1, Silvana Fuina1, Giacomo Scarascia Mugnozza1,
Carlo Alberto Campiotti2 & Giuliano Vox1
1 Department of Agricultural and Environmental Science DISAAT, University of Bari, Bari, Italy, [email protected]
2 ENEA - Italian National Agency for New Technologies, Energy and Sustainable Economic Development - Technical
Unit Energy Efficiency - Agriculture Unit, Rome, Italy.
Abstract
The Urban Heat Island (UHI) phenomenon induces harmful outdoor comfort conditions, an
increase in pollutants concentration, an excessive energy consumption related to the greater use of air conditioning systems and a raise of the frequency and magnitude of electricity demand peaks. In the Mediterranean area the urban warming and the solar heat gain in
buildings need to be controlled in a sustainable way for keeping the indoor temperature at
comfortable values. Green roofs and green walls can mitigate the heat events related to UHI,
lower the indoor temperatures, cut energy loads on buildings, enhance human thermal comfort conditions and increase the buildings thermal insulation in winter. Experimental tests
were carried out at the University of Bari (Italy) starting from summer 2014, aiming to analyze the influences of different climbing plants, as main components of green systems, applied on building walls. Three vertical walls, made of perforated bricks, were built. They were
equipped with a sealed structure, on their backside, in order to realize prototypes of buildings
in scale. The first wall was covered with Pandorea jasminoides variegated, the second with
Rhyncospermum jasminoides, the third wall was kept uncovered and used as control. Several
climatic parameters concerning the walls and the ambient conditions were collected during
the experimental test by means of a data logger and sensors. High definition infra-red images for each wall were recorded using a Thermal Imaging Camera for analyzing the surface
temperature of the plants and of the walls. The daylight temperatures observed on the walls
protected with plants during warm days were lower than the respective temperatures of the
control wall up to 5 °C; the nighttime temperatures observed during cold days were higher
than the respective temperatures of the control wall up to 3°C.
Keywords
Energy savings, passive systems, urban heat island, surface temperature, infrared images.
857