Emmett McNamara Professional Portfolio | Page 3
2
1,143
1,143
1,143
1,143
1,143
FSR(34)006
E
F
E
42mm dia. galvanised steel balustrade
top rail
F
Detail 2 - Bridge Balustrade
42mm dia. galvanised steel handrail,
welded to 18mm dia galvanised rod
93
New Community Facility
Bridge Elevation
Bridge Elevation
FSR(34)001
Middle Park
Future Buildings
+73.000
1 Level +1
100 x 100 RSA diagonal bracing
FSR(34)001
3,100
1,815
LW-52 (VL)
Block P South Elevation (Canal) Pt 4
P3 63mm thk. paving on nominally 20mm
epoxy resin mortar on 10mm thl. galv.
steel plate
Framing 100 x 100 RSA
300 x 100 PFC fixed to retaining wall
Anodised aluminium sheet lining soffitbracing
Gibson Terrace
Student Centre
Future Buildings
Edge of concrete slab
Lateral Street Context Elevation
2
2
+70.000
0 Level +0
Continuous 8mm thk galvanised
steel stringer
BP
West Bridge Long Section
1,105
42mm dia. galvanised
steel balustrade top rail
P3 Charcon Courtstone 63mm
thk.Paving on epoxy mortar
1,105
1,105
1,105
1,105
1,110
900
90
Slope 1:57
100x100 RSA diagonal
bracing
Bridge Cross Section
Bridge Cross Section
FSR(34)005
65
FSR(34)005
300x100 PFC
Dundee Street
Kwik Fit Buildings
Lateral Street
Canal Street
Future Buildings
Line of top paving
42mm dia. galvanised steel
handrail
Union Canal
Q
220 x 80mm galv. and painted steel
ßat plate welded to post and bolted to
stringer
Outline of Gibson Terrace Tenements
Future Buildings
1:25
2
Block P West Ctyrd Elevation
100x100 RSA framing
BP
2,025
West Bridge Side Elevation
1:25
M
Gibson Terrace Context Elevation
E
Retaining wall
A
06/06/11
Rev! Date!
M i d d l e
P a r k
9 Harrison Gardens, Edinburgh, EH11 1SJ
0131 313 1999 www.ama-ltd.co.uk
2
900
FSR(34)001
FSR(34)001
Bridge Long Section
Bridge Long Section
C o u r t y a r d
300x100mm galv.
PFC Stringer
455mm deep x 8mm thk galv.
steel plate Stringer Þxed with
countersunk Allen head bolts to
300x100mm PFC galv. stringer
name: Context Elevations Sheet 1 of 2
U n i o n
Gibson Terrace
A
Existing Tenement Buildings
date: Jan.2011
Dundee Street Context Elevation
Plan with Paving omitted
C a n a l
dwg no: FSR(PA)017A
Retail Unit
scale: 1:250
format: A1 status:
BP
2,640
Plan
Plans of West Bridge
Work to ?gured dimensions only: do not scale from this drawing. All dimensions to be checked on
site prior to fabrication. Read in conjunction with all other relevant drawings speci?cations and
schedules.
© Allan Murray Architects Ltd. 2011. All rights described in Chapter IV of the Copyright, Designs
and Patents Act 1988 have been generally asserted.
FSR(PA)+(SK)Layouts 110512.pln 6/8/11
[archicad]
[archicad]
Credit: Allan Murray Visualisation Department
Fountainbridge Student Housing, Edinburgh
[Allan Murray Architects]
50 x 12mm galvanised steel ßat
bar balustrade bottom rail, welded
to balustrade support
+73.000
1 Level +1
100x100 RSA framing
beyond
380x100 PFC
A
Anodised aluminium
sheet lining to sofÞt
revision
07:08:12 Amended balustrade as per latest E&A drawing
date
notes
project: Fountainbridge Student Residencies
100x100 RSA diagonal
bracing
Fountainbridge Student Residencies
Kwik Fit Buildings
N
P3 63mm thk. paving on 20mm
nominal epoxy resin mortar on
10mm thk. galv. steel plate
Edge of concrete
retaining wall
e t
S t r e
1
G i b s o n
T e r r a c e
Fit
42mm dia. galvanised steel
balustrade top rail
8 beds room windows changed in Block P
FSR(34)001
d e e
D u n
K w i k
Detail 1 - Bridge Balustrade
42mm dia. galvanised
steel balustrade top rail
Description
Bridge Long Section
3
Retaining wall
1,783
06/06/11 8 beds room windows changed in Block P
1,110
A
P
F
FSR(34)006
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
N
client:
Cityheart
title :
2,640
West Bridge Layout
dwg no:
FSR(34)004 A
date: July 2011
1:25
BP
West Bridge Cross Section
1:25
scale: 1:25
format: A1
status: S1
a : 9 Harrison Gardens, Edinburgh, EH11 1SJ
t : (0)131 313 1999
f : (0)131 313 1666
e : [email protected]
w : www.ama-ltd.co.uk
© Allan Murray Architects Ltd 2012. All rights described in Chapter IV of the Copyright, Designs and Patents Act
Projects:FSR Fountainbridge Student Residencies:Layouts:FSR(34)Layouts.pln 06/09/2012 22:01
1988 have been generally asserted.
All areas and dimensions estimated in these drawings are provided to aid discussion only. Verification will be
required, based on survey information and detailed design development, as well as Planning and Building
Control requirements. Any discrepancies to be brought to the attention of the SO