Emmett McNamara Professional Portfolio | Page 3

2 1,143 1,143 1,143 1,143 1,143 FSR(34)006 E F E 42mm dia. galvanised steel balustrade top rail F Detail 2 - Bridge Balustrade 42mm dia. galvanised steel handrail, welded to 18mm dia galvanised rod 93 New Community Facility Bridge Elevation Bridge Elevation FSR(34)001 Middle Park Future Buildings +73.000 1 Level +1 100 x 100 RSA diagonal bracing FSR(34)001 3,100 1,815 LW-52 (VL) Block P South Elevation (Canal) Pt 4 P3 63mm thk. paving on nominally 20mm epoxy resin mortar on 10mm thl. galv. steel plate Framing 100 x 100 RSA 300 x 100 PFC fixed to retaining wall Anodised aluminium sheet lining soffitbracing Gibson Terrace Student Centre Future Buildings Edge of concrete slab Lateral Street Context Elevation 2 2 +70.000 0 Level +0 Continuous 8mm thk galvanised steel stringer BP West Bridge Long Section 1,105 42mm dia. galvanised steel balustrade top rail P3 Charcon Courtstone 63mm thk.Paving on epoxy mortar 1,105 1,105 1,105 1,105 1,110 900 90 Slope 1:57 100x100 RSA diagonal bracing Bridge Cross Section Bridge Cross Section FSR(34)005 65 FSR(34)005 300x100 PFC Dundee Street Kwik Fit Buildings Lateral Street Canal Street Future Buildings Line of top paving 42mm dia. galvanised steel handrail Union Canal Q 220 x 80mm galv. and painted steel ßat plate welded to post and bolted to stringer Outline of Gibson Terrace Tenements Future Buildings 1:25 2 Block P West Ctyrd Elevation 100x100 RSA framing BP 2,025 West Bridge Side Elevation 1:25 M Gibson Terrace Context Elevation E Retaining wall A 06/06/11 Rev! Date! M i d d l e P a r k 9 Harrison Gardens, Edinburgh, EH11 1SJ 0131 313 1999 www.ama-ltd.co.uk 2 900 FSR(34)001 FSR(34)001 Bridge Long Section Bridge Long Section C o u r t y a r d 300x100mm galv. PFC Stringer 455mm deep x 8mm thk galv. steel plate Stringer Þxed with countersunk Allen head bolts to 300x100mm PFC galv. stringer name: Context Elevations Sheet 1 of 2 U n i o n Gibson Terrace A Existing Tenement Buildings date: Jan.2011 Dundee Street Context Elevation Plan with Paving omitted C a n a l dwg no: FSR(PA)017A Retail Unit scale: 1:250 format: A1 status: BP 2,640 Plan Plans of West Bridge Work to ?gured dimensions only: do not scale from this drawing. All dimensions to be checked on site prior to fabrication. Read in conjunction with all other relevant drawings speci?cations and schedules. © Allan Murray Architects Ltd. 2011. All rights described in Chapter IV of the Copyright, Designs and Patents Act 1988 have been generally asserted. FSR(PA)+(SK)Layouts 110512.pln 6/8/11 [archicad] [archicad] Credit: Allan Murray Visualisation Department Fountainbridge Student Housing, Edinburgh [Allan Murray Architects] 50 x 12mm galvanised steel ßat bar balustrade bottom rail, welded to balustrade support +73.000 1 Level +1 100x100 RSA framing beyond 380x100 PFC A Anodised aluminium sheet lining to sofÞt revision 07:08:12 Amended balustrade as per latest E&A drawing date notes project: Fountainbridge Student Residencies 100x100 RSA diagonal bracing Fountainbridge Student Residencies Kwik Fit Buildings N P3 63mm thk. paving on 20mm nominal epoxy resin mortar on 10mm thk. galv. steel plate Edge of concrete retaining wall e t S t r e 1 G i b s o n T e r r a c e Fit 42mm dia. galvanised steel balustrade top rail 8 beds room windows changed in Block P FSR(34)001 d e e D u n K w i k Detail 1 - Bridge Balustrade 42mm dia. galvanised steel balustrade top rail Description Bridge Long Section 3 Retaining wall 1,783 06/06/11 8 beds room windows changed in Block P 1,110 A P F FSR(34)006 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 N client: Cityheart title : 2,640 West Bridge Layout dwg no: FSR(34)004 A date: July 2011 1:25 BP West Bridge Cross Section 1:25 scale: 1:25 format: A1 status: S1 a : 9 Harrison Gardens, Edinburgh, EH11 1SJ t : (0)131 313 1999 f : (0)131 313 1666 e : [email protected] w : www.ama-ltd.co.uk © Allan Murray Architects Ltd 2012. All rights described in Chapter IV of the Copyright, Designs and Patents Act Projects:FSR Fountainbridge Student Residencies:Layouts:FSR(34)Layouts.pln 06/09/2012 22:01 1988 have been generally asserted. All areas and dimensions estimated in these drawings are provided to aid discussion only. Verification will be required, based on survey information and detailed design development, as well as Planning and Building Control requirements. Any discrepancies to be brought to the attention of the SO