e-Showcase | Page 4

Power Curves 100 NPS 100C-24 Class III/A Power Curve 24m Rotor, Standard Conditions* 90 80 70 60 50 wind speed (m/s) electric power (kWe) 1 2 3 -0.5 -0.5 1.2 4 5 6 7 8 9 10 7.2 14.5 24.7 37.9 58.7 74.8 85.1 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 90.2 94.7 95.3 95.1 94.2 92.9 91.2 88.9 87.1 84.1 81.3 78.6 76.1 74.3 71.7 Power (kWe) 40 30 20 10 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Wind speed at hub height (m/s) 450 Annual Energy Production: 24-Metre Rotor Standard Conditions,* Rayleigh Wind Distribution 400 (mph) 11 12 13 14.5 16 17 Average annual wind speed (m/s) 5.0 5.5 6.0 6.5 7 7.5 Annual energy output (MWh/yr) 196 240 284 325 364 399 Annual Energy Output (MWh/yr) 350 300 250 200 150 4.5 5 5.5 6 6.5 7 Average Annual Wind Speed (m/s) Northern Power Systems * Standard conditions: air density of 1.225 kg/m3, equivalent to 15°C (59°F) at sea level NPS, Northern Power, SmartView & Hurricane Resistant are trademarks of Northern Power Systems. 29 Pitman Road Barre, Vermont, 05641 USA UK Tel: 0808 234 6788 northernpower.com 7.5 8